Accurate Powertech India Pvt. Ltd.

750 KVA Gensets, 1500 KVA Gensets, Aircooled Gensets, Watercooled Gensets, Gensets (Generators / Diesel Engines / DG Sets) Dealer, Supplier, Pune, Maharashtra, India

Gensets - 750 kVA - 1500 kVA -

750kva-1500-kva

Canopy :

  • Ease of Access and Serviceability
  • Aesthetically designed, weather and Sound resistant enclosure
  • Insulation conforms to UL94-HF1 class for Flammability

Controller :

  • Microprocessor based
  • Graphical LCD display
  • Best in class monitoring and diagnostic capability
  • Integrable with AMF, synchronization & communication configurations

Engine :

  • O2E Series: Low emission, high efficiency engines
  • Compact, Robust and Rugged Design
  • 500 hours lube-oil change period
  • Integral set - mounted radiator system, designed & tested for 50ºC ambient temperature


Alternator :

  • Best In Class Efficiency
  • Special Windings to Reduce Harmonics
  • Vacuum Pressure Impregnation and epoxy gel coating on the winding




Engine capacity does matter :

Engine capacity (cc) plays a vital role in Genset performance. Higher engine capacity leads to a robust and stable Genset performance.

Higher engine capacity also enables the Genset to respond quickly & positively to sudden load additions.

Prime Rating at rated rpm (as per IS08528 )1 kVA 750 HD 900 HD 1010 HD 1250 HD 1500 HD
kW 600
720 808 1000
1200
Genset Model   KG1-750WS KG1-900WS
KG1-1010WS KG1-1250WS
KG1-1500WS
Frequency Hz 50
Power factor lagging 0.8
Voltage V 415 30
Governing class (As per ISO 8528 Part-V)   G3
DG set Noise level at 1 Mtr with Genset Canopy dBA ≤75 Contact Kirloskar Oil Engines Ltd. for Details
Fuel Consumption* At 100 % Load Ltrs/hr 154 197 199 250 310
At 75 % Load 126.4 163 155 189 230
At 50 % Load 89.7 120 112 134 157
Fuel tank capacity Ltrs 990 990 990 880 880
Weight of genset with canopy (approx.) Dry Kg 8300 13600 13200 13075+
Overall dimensions of genset A Length mm 6800 8000 7800 5650+
Width mm 2300 2300 2300 2300+
Height mm 2713 2713 2713 2680+
Electrical Battery starting voltage Volts-DC 24
ENGINE
Engine Model (Parent Engine)   DV12ETA DV16ETA DV16ETA 12K4300-E2 12K4300-E1
Rated output (Prime Continuous rating as per ISO No. of cylinder 3046) kW 663 799  889 1090 1294
HP 901 1086 1210 1482 1760
  Number 12 16 12
Cubic capacity2 Ltrs 23.88 31.84 51.73
Bore x Stroke mm 130 x 150 170 x 190
Rated Speed RPM 1500
Aspiration NA/IC/TA TA
Lube Oil change period hrs 500
Lube Oil Sump Capacity Ltrs 73 130 130 265
Coolant Capacity with Radiator Ltrs 175 180  180 210
ALTERNATOR
Insulation Class   Class H
Ingression Protection   IP 23
Alternator Efficiency (at 100% load) 0.8 pf*   94.6 95.3 95.1 95.7 95.4
Alternator Efficiency (at               75% load) 0.8 pf*   94.9 95.5 95.4 95.9 95.8
Permissible Voltage Dip at Full Load 0.8 pf Lag   ≤ 20 %
Time Permitted to build up rated voltage at             rated RPM   < 1 sec, provided engine should reach rated RPM
Short Circuit Withstand Time sec 3 Times rated current for "10 sec"
Overload Withstand Capacity % 10% overload for one hour once in 12 hours